Earth Leakage Breaker (1GDRC5 ELB)


The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called ‘Leakage Current’.

Earth Leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth Leakage and its associated hazard can be prevented by residual current device (RCD), similar to that of a residual current circuit breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).

Features

- Simple and Robust operating mechanism.
- Rotary handle with ON/Off indication
- Dual termination for Bus Bar as well as cable connection
- Advance Neautral
- Test Button for regular inspection

Technical information 

Model Number   1GDR-2P 1GDR-4P
Tripping Mode   Electro-Magnetic type Electro-Magnetic type
Pole No. Pole 2P = 1P + N (2 modular width) 4P = 3P + N (4 modular width)
Standard Conformity   IEC 61008-1 IEC 61008-1
Rated Current (In) A 16, 25, 40, 63 16, 25, 40, 63
Sensitivity (I △ n) mA 30, 100, 300, 500 30, 100, 300, 500
Residual Tripping Current Range   0.5I △ n-1I △ n 0.5I △ n-1I △ n
Rated Voltage (Un) Vac 240 240 / 415
Rated Insulation Voltage (Ui) V 660 660
Rated Frequency Hz 50/60 50/60
Rated Making & Breaking Capacity A 630 630
Type   AC: Alternative Circuit only
A: AC and DC both
G: Time delay type
AC: Alternative Circuit only
A: AC and DC both
G: Time delay type
Tripping Time S ≤0.1 ≤0.1
Shortcircuit Withstand Capacity kA 6 6
Ambient Temperature oC -25 to +40 -25 to +40
Electrical Mechanical Operation cycles 4000 4000
Mounting   Din Rail (35 * 7.5) mm Din Rail (35 * 7.5) mm
Degree of Protection   IP 20 IP 20
Terminal Capacity (max) mm2 25 25
Connection Terminals   Screw Terminals 2.0Nm Screw Terminals 2.0Nm
Certificate   CE CE

Ordering Information

■GDR - 4 - 63 - 030 -   - Casing
 |   |   |   |   |   |
1:1 Series
2:2 Series
3:3 Series
4:4 Series
5:5 Series
6:6 Series
7:7 Series
8:8 Series
9:9 Series
  Poles:
2=2 poles;
4=4 poles;
  Rated Current:
16=16A;
20=20A;
25=25A;
32=32A;
40=40A;
63=63A;
80=80A;
100=100A;
125=125A;
  Residual Current
Sensitivity:
030=30mA
100=100mA
300=300mA
500=500mA
  Type:
Blank=AC Type
A= AC/DC
Type
G= Time
delay Type
  C1=C1 outline;
C2=C2 outline;
C3=C3 outline;

For Double Pole (1P+N)

Current Rating(A) Sensitivity (mA) Cat. No.
25 30 1GDR225030C5
25 100 1GDR225100C5
40 30 1GDR240030C5
40 100 1GDR240100C5
63 30 1GDR263030C5
63 100 1GDR263100C5
For Four Pole (3P+N)

Current Rating (A) Sensitivity (mA) Cat. No.
25 30 1GDR425030C5
25 100 1GDR425100C5
40 30 1GDR440030C5
40 100 1GDR440100C5
63 30 1GDR463030C5
63 100 1GDR463100C5

Dimension

GEL22-63C RCCB/RCD

If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day.

Product*
E-mail *
For example : Peter@greegoo.com
Message*
Your Name*
For example : Peter Xiao. First name and Last name
Company
For example : Greegoo Electric Co.,Ltd
Telephone*
For example : 0086-577-62776000(Country code + City code + Tel numbers)
  
 

Related Products: