Earth Leakage Breakers (1GDRC5)
|
Earth Leakage Breaker (1GDRC5 ELB)
The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called ‘Leakage Current’.
Earth Leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth Leakage and its associated hazard can be prevented by residual current device (RCD), similar to that of a residual current circuit breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB).
Features
- Simple and Robust operating mechanism.
- Rotary handle with ON/Off indication
- Dual termination for Bus Bar as well as cable connection
- Advance Neautral
- Test Button for regular inspection
Technical information
| Model Number |
|
1GDR-2P |
1GDR-4P |
| Tripping Mode |
|
Electro-Magnetic type |
Electro-Magnetic type |
| Pole No. |
Pole |
2P = 1P + N (2 modular width) |
4P = 3P + N (4 modular width) |
| Standard Conformity |
|
IEC 61008-1 |
IEC 61008-1 |
| Rated Current (In) |
A |
16, 25, 40, 63 |
16, 25, 40, 63 |
| Sensitivity (I △ n) |
mA |
30, 100, 300, 500 |
30, 100, 300, 500 |
| Residual Tripping Current Range |
|
0.5I △ n-1I △ n |
0.5I △ n-1I △ n |
| Rated Voltage (Un) |
Vac |
240 |
240 / 415 |
| Rated Insulation Voltage (Ui) |
V |
660 |
660 |
| Rated Frequency |
Hz |
50/60 |
50/60 |
| Rated Making & Breaking Capacity |
A |
630 |
630 |
| Type |
|
AC: Alternative Circuit only
A: AC and DC both
G: Time delay type |
AC: Alternative Circuit only
A: AC and DC both
G: Time delay type |
| Tripping Time |
S |
≤0.1 |
≤0.1 |
| Shortcircuit Withstand Capacity |
kA |
6 |
6 |
| Ambient Temperature |
oC |
-25 to +40 |
-25 to +40 |
| Electrical Mechanical Operation |
cycles |
4000 |
4000 |
| Mounting |
|
Din Rail (35 * 7.5) mm |
Din Rail (35 * 7.5) mm |
| Degree of Protection |
|
IP 20 |
IP 20 |
| Terminal Capacity (max) |
mm2 |
25 |
25 |
| Connection Terminals |
|
Screw Terminals 2.0Nm |
Screw Terminals 2.0Nm |
| Certificate |
|
CE |
CE |
Ordering Information
| ■GDR |
- |
4 |
- |
63 |
- |
030 |
- |
|
- |
Casing |
| | |
|
| |
|
| |
|
| |
|
| |
|
| |
1:1 Series
2:2 Series
3:3 Series
4:4 Series
5:5 Series
6:6 Series
7:7 Series
8:8 Series
9:9 Series |
|
Poles:
2=2 poles;
4=4 poles; |
|
Rated Current:
16=16A;
20=20A;
25=25A;
32=32A;
40=40A;
63=63A;
80=80A;
100=100A;
125=125A; |
|
Residual Current
Sensitivity:
030=30mA
100=100mA
300=300mA
500=500mA |
|
Type:
Blank=AC Type
A= AC/DC
Type
G= Time
delay Type |
|
C1=C1 outline;
C2=C2 outline;
C3=C3 outline; |
For Double Pole (1P+N)
| Current Rating(A) |
Sensitivity (mA) |
Cat. No. |
| 25 |
30 |
1GDR225030C5 |
| 25 |
100 |
1GDR225100C5 |
| 40 |
30 |
1GDR240030C5 |
| 40 |
100 |
1GDR240100C5 |
| 63 |
30 |
1GDR263030C5 |
| 63 |
100 |
1GDR263100C5 |
|
For Four Pole (3P+N)
| Current Rating (A) |
Sensitivity (mA) |
Cat. No. |
| 25 |
30 |
1GDR425030C5 |
| 25 |
100 |
1GDR425100C5 |
| 40 |
30 |
1GDR440030C5 |
| 40 |
100 |
1GDR440100C5 |
| 63 |
30 |
1GDR463030C5 |
| 63 |
100 |
1GDR463100C5 |
|
Dimension
 |
If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day.